More D Four types of waters have been specified, with three additional grades that can be applied to the four types. The grade specifications specifically address contaminants of microbiological origin. Starting with this revision, these types of waters may be produced with alternate technologies as long as the appropriate constituent specifications are met. The electrical conductivity and resistance, pH, silica, sodium, chlorides, TOC, endotoxins, and microbiological contamination shall be tested to meet the requirements prescribed.

Author:Zulukinos Akinogul
Country:Singapore
Language:English (Spanish)
Genre:Marketing
Published (Last):27 August 2018
Pages:291
PDF File Size:19.60 Mb
ePub File Size:5.85 Mb
ISBN:599-6-47031-893-7
Downloads:22518
Price:Free* [*Free Regsitration Required]
Uploader:Akinogis



More D In its most common form, this test method is used to measure organic carbon as a means of monitoring organic impurities in high purity process water used in industries such as nuclear power, pharmaceutical, and electronics. Scope 1. This method is for laboratory or grab sample applications and has been subjected to an interlaboratory study under the guidelines of D Test Method D can be used for on-line determinations. The test method utilizes persulfate or ultraviolet oxidation of organic carbon, or both coupled with a CO2 selective membrane to recover the CO2 into deionized water.

The change in conductivity of the deionized water is measured and related to carbon concentration in the oxidized sample. Inorganic carbon is determined in a similar manner without the oxidation step. In both cases, the sample is acidified to facilitate CO2 recovery through the membrane.

The chemometric model includes the temperature dependence of the equilibrium constants and the specific conductances resulting in linear response of the method over the stated range of TOC. Also, use of two measurement channels allows determination of CO2 in the sample independently of organic carbon.

Isolation of the conductivity detector from the sample by the CO2 selective membrane results in a very stable calibration, with minimal interferences. See Test Method D No other units of measurement are included in this standard. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.